Jul 20th 2026

Light Bee Diagnostic Codes

Light Bee  diagnostic identification chart
(2019.02.22)
No.
LED
Diagnostic explanation
Diagnostic code
Solution
Number of flash times Shown on instrument
1 1 normal operation condition ---- ----
2 2 controller power tube malfunction Er-208 turn off power switch and turn on again
3 3 controller hardware over current protection Er-207 leave throttle to idle position and twist throttle again
4 4 controller software over current protection Er-206 auto recovery
5 5 motor main cable phase malfunction Er-205 turn off power switch and turn on again
6 6 motor Hoare coil malfunction Er-204 turn off power switch and turn on again
7 7 motor stall protection ---- leave throttle to idle position and twist throttle again
8 8 controller level. 1 over temperature protection Er-202 turn off power switch and turn on again
9 9 controller level. 2 over temperature protection Er-201 turn off power switch and turn on again
10 10 motor level. 1 over temperature protection Er-216 turn off power switch and turn on again
11 11 motor level. 2 over temperature protection Er-215 turn off power switch and turn on again
12 12 battery level.2 over voltage protction ---- leave throttle to idle position and twist throttle again
13 13 battery level.2 low voltage protction Er-213 leave throttle to idle position and twist throttle again
14 14 throttle rush-out protection Er-212 turn off power switch and turn on again
15 15 Throttle to controller signal wire short-circuit Er-211 turn off power switch and turn on again
16 16 brake protection ---- auto recovery
17 21 controller current sampling failure Er-209 turn off power switch and turn on again
18 22 side stand protection Er-224 auto recovery
19 23 tilt swith protection Er-223 leave throttle to idle position and twist throttle again
20 24 key switch port power failure protection Er-222 turn off power switch and turn on again
21 25 battery low voltage protection (level. 1) Er-221 turn off power switch and turn on again
22 27 CAN communication malfunction ER 217 auto recovery
23 ---- communication malfunction( ER 002 auto recovery
24 28 battery premier discharge(voltage) protection(level. 2) Er-105 charging battery to recovery
25 29 battery discharge low temperature protection(level. 2) Er-114 turn off power switch and turn on again
26 30 battery over temperature protection(level. 1) Er-219 turn off power switch and turn on again
27 31 controller and battery 485 communication no response
Er-216
auto recovery
28 32 controller and battery 485 communication unmatch auto recovery
29 33 battery SOC low capacity protection Er-218 turn off power switch and turn on again
30 17 motor temperature sensor malfunction Er-200 auto recovery
31 18 battery BMS discharging MOS malfunction Er-107 recovery after fault removal
32 18 battery BMS charging MOS malfunction Er-106 recovery after fault removal
33 19 battery BMS MOS temperature sensor malfunction Er-102 auto recovery
34 19 battery cell temperature sensor malfunction ---- auto recovery
35 20 battery discharge over temperature protection(level. 2) Er-116 temperature drop to working temperature to recovery
36 26 battery cell charging over temperature protection(level. 2) ---- temperature drop to working temperature to recovery
37 34 battery cell charging low temperature protection(level. 2) ---- temperature rise to working temperature to recovery
38 20 battery discharging MOS over temperature protection(level. 2) ---- temperature drop to working temperature to recovery
39 26 battery charging MOS over temperature protection(level. 2) ---- temperature drop to working temperature to recovery
40 20 battery BMS soft start circuit over temperature protection(level. 2) ---- temperature drop to working temperature to recovery
41 35 battery over current protection (level.3) ---- auto recovery
42 ---- battery BMS discharge MOS over temperature protection(level. 1) Er-120 temperature drop to working temperature to recovery
43 ---- battery premier over discharge(voltage) protection(level. 1) Er-119 auto recovery
44 ---- battery discharge low temperature protection(level. 1) Er-118 temperature rise to working temperature to recovery
45 ---- battery discharge over temperature protection(level. 1) Er-117 temperature drop to working temperature to recovery